Stay Cool, Scale Fast
Supercharging AI Factories for Enterprise
ASUS AI POD with NVIDIA HGX™ Rubin NVL8
1Full Liquid-cooled
CPU and GPU Sled are liquid-cooled
2Efficiency-Driven Cooling
Long-term savings through reduced power consumption
3Better PUE
Maximizes long-term ROI at scale
4High-Density Data Center
Designed for high-capacity liquid-cooling infrastructure
Faster Time-to-Train
- Massive parallel GPU scaling
- Ultra-low latency interconnect
- Sustained performance under full load
Balanced Performance & Efficiency
- Low-latency processing
- High throughput
- Cost-efficient operation
Deploy with Confidence
- Faster time-to-deployment
- Consistent uptime and reliability
- Simplified maintenance and flexibility
NVIDIA HGX™ Rubin NVL8,
Powering Every AI and HPC Workload
Boost Token Factory Throughput
*Source: NVIDIA. Projected performance, subject to change. Token throughput based on Kimi K2-Thinking (FTL≤500ms, ISL=4K, OSL=4K); HGX Rubin NVL8 with Sparse NVFP4 vs. HGX B200 with Dense NVFP4. Training comparison based on DeepSeek-R1 pretrained on 15T tokens, 4K sequence length.
Accelerating the Next Generation of Agentic AI
A 2U Compute Tray Engineered for Density and Uptime
-
-
1 2 31IO Switch Board w / manifold
2CPU HPM /cold plate
3HGX Rubin NVL8 - L8
-
1 2 31UQD08
2600A Busbar Clip
3UQD08
-
1 2 3 4 5 6 7 8 9 10 111BlueField-4
2E1.S x8
3IO Board
4Power Button
5Locate Button
6BMC RST Button
7UART
81GB Lan
9BMC Mini DP
10USB 3.2
11DM LAN
-
-
-
Leading the Era of Super-Intelligent AI Reasoning
XR R1I12B-M1BLFS
-
-
CPU18x Intel Xeon6 6776P ProcessorsGPU72 NVIDIA Rubin GPUCooling100% Liquid Cooled DesignNetworking72 x OSFP Ports via NVIDIA ConnectX-99 x NVIDIA BlueField-4 DPUsRack Power
Shelf4*110kW
1x OOB MGMT Switch 1GBe
2 x 3RU Power Shelf 110KW
9 x Compute Trays
72 x NVIDIA Rubin NVL8 GPUs per tray
18 x Intel Xeon6 6776P CPUs per tray2 x 3RU Power Shelf 110KW
-
ASUS AI POD with NVIDIA HGX™ Rubin NVL8
North-South Networking
North-South Networking
Power Shelves
Management Node
File System
Object Storage
Management switch
Power Shelves
9 x ASUS XANR1I-E12LR
• 18 x Intel® Xeon® 6 processors
• 72 x NVIDIA Rubin GPUs
Power Shelves
ASUS Professional Services
Your Trusted Partner from Factory to Future
-
Testing and Validation
-
Packaging and Delivering
-
Deployment and Management
FAQs
-
How do I know which ASUS rack — XR R1I12B-M1BLFS or XR R1I12B-M1BHFS — fits my data center?How do I know which ASUS rack — XR R1I12B-M1BLFS or XR R1I12B-M1BHFS — fits my data center? It depends primarily on your data center's cooling infrastructure and rack power architecture. The 2U XA NR1I-E12LR is designed for full direct liquid cooling (DLC), while the 3U XA NR1I-E12L uses a hybrid-cooling architecture. Depending on the deployment environment, different CDU and power configurations, including in-row or in-rack CDU and busbar or PSU-based solutions, can be evaluated. ASUS can assess the customer's facility cooling and power infrastructure to recommend the appropriate rack configuration.
-
Does the HGX Rubin NVL8 platform require liquid cooling, or can it run in an existing air-cooled data center?Does the HGX Rubin NVL8 platform require liquid cooling, or can it run in an existing air-cooled data center? The HGX Rubin NVL8 platform requires liquid cooling for the GPUs. ASUS offers both full direct liquid cooling (DLC) and hybrid-cooling designs to support different data center environments. The 2U XA NR1I-E12LR is designed for full DLC, while the 3U XA NR1I-E12L combines liquid cooling for the GPUs with air cooling for other components. Existing data centers should be assessed for cooling capacity and facility readiness before deployment.
-
What are the benefits of liquid cooling compared to traditional air cooling?What are the benefits of liquid cooling compared to traditional air cooling? Liquid cooling provides more efficient heat removal for high-density GPU systems by transferring heat directly through the liquid cooling loop, reducing reliance on server-level air cooling. Actual efficiency improvements depend on data center conditions, cooling architecture, and operating environment.
-
What are the power and cooling requirements per rack for this platform?What are the power and cooling requirements per rack for this platform? A full L11 rack supports nine XA NR1I-E12LR compute trays with 72 NVIDIA Rubin GPUs and 18 Intel Xeon 6776P processors. The rack has a system power budget of approximately 216 kW and features a fully liquid-cooled architecture for both CPUs and GPUs. A 2+2 redundant 110 kW power shelf design and a 5000A rack busbar provide the required rack-level power infrastructure.
-
What deployment and after-sales support does ASUS provide for global rollouts of this platform?What deployment and after-sales support does ASUS provide for global rollouts of this platform? ASUS provides deployment planning and technical support for HGX Rubin NVL8 rack-scale solutions, including infrastructure assessment, rack integration, and system validation. Deployment and after-sales service options may vary by region and project requirements. ASUS teams can work with customers to define the appropriate service scope for each deployment.